Automat_spozywczy/models/134700.diagram

78 lines
3.1 KiB
Plaintext
Raw Normal View History

2021-01-31 15:32:36 +01:00
format 224
2021-01-31 01:11:58 +01:00
classinstance 128044 class_ref 128044 // Serwisant
name "" xyz 17 4 2000 life_line_z 2000
2021-01-31 22:07:16 +01:00
classinstance 128172 class_ref 141996 // NaprawaAutomatu
name "KontrolerAutomatu" xyz 165 5 2000 life_line_z 2000
classinstance 128300 class_ref 142124 // ManagerDiagnozy
name "" xyz 617 4 2000 life_line_z 2000
2021-01-31 01:11:58 +01:00
classinstance 128428 class_ref 135212 // Raport
2021-01-31 22:07:16 +01:00
name "" xyz 859 83 2000 life_line_z 2000
2021-01-31 01:11:58 +01:00
note 129196 "Diagnoza czy SystemOperacyjny?"
2021-01-31 22:07:16 +01:00
xyzwh 412 398 2005 155 59
2021-01-31 01:11:58 +01:00
note 129836 "Moze bardziej jest to przeprowadzenie diagnozy niz \"wlaczenie narzedzi diagnostycznych?\""
2021-01-31 22:07:16 +01:00
xyzwh 369 299 2000 277 73
classinstance 130220 class_ref 128300 // SystemOperacyjny
name "" xyz 448 4 2005 life_line_z 2000
2021-01-31 01:11:58 +01:00
durationcanvas 128556 classinstance_ref 128044 // :Serwisant
xyzwh 48 69 2010 11 40
end
2021-01-31 22:07:16 +01:00
durationcanvas 128684 classinstance_ref 128172 // KontrolerAutomatu:NaprawaAutomatu
xyzwh 288 70 2010 11 67
2021-01-31 01:11:58 +01:00
end
2021-01-31 22:07:16 +01:00
durationcanvas 128940 classinstance_ref 128300 // :ManagerDiagnozy
xyzwh 678 79 2010 11 148
overlappingdurationcanvas 130604
xyzwh 684 87 2020 11 38
end
overlappingdurationcanvas 131116
xyzwh 684 152 2020 11 25
end
2021-01-31 01:11:58 +01:00
end
durationcanvas 129324 classinstance_ref 128428 // :Raport
2021-01-31 22:07:16 +01:00
xyzwh 883 133 2010 11 50
2021-01-31 01:11:58 +01:00
end
2021-01-31 22:07:16 +01:00
durationcanvas 129964 classinstance_ref 128044 // :Serwisant
xyzwh 48 158 2010 11 69
end
durationcanvas 130348 classinstance_ref 130220 // :SystemOperacyjny
xyzwh 512 86 2010 11 61
2021-01-31 01:11:58 +01:00
end
msg 128812 synchronous
from durationcanvas_ref 128556
to durationcanvas_ref 128684
2021-01-31 15:32:36 +01:00
yz 71 2015 explicitmsg "1. wlaczNarzedziaDiagnostyczne()"
2021-01-31 01:11:58 +01:00
show_full_operations_definition default show_class_of_operation default drawing_language default show_context_mode default
2021-01-31 15:32:36 +01:00
label_xy 57 53
2021-01-31 01:11:58 +01:00
msg 129452 synchronous
from durationcanvas_ref 128940
to durationcanvas_ref 129324
2021-01-31 22:07:16 +01:00
yz 172 2015 explicitmsg "<<create>> 1.3. stworzRaportDiagnozy"
2021-01-31 01:11:58 +01:00
show_full_operations_definition default show_class_of_operation default drawing_language default show_context_mode default
2021-01-31 22:07:16 +01:00
label_xy 662 191
msg 130092 synchronous
2021-01-31 01:11:58 +01:00
from durationcanvas_ref 128940
2021-01-31 22:07:16 +01:00
to durationcanvas_ref 129964
yz 216 2020 explicitmsg "1.4 ZwrocRaport()"
2021-01-31 01:11:58 +01:00
show_full_operations_definition default show_class_of_operation default drawing_language default show_context_mode default
args "raport : Raport"
2021-01-31 22:07:16 +01:00
label_xy 171 199
msg 130476 synchronous
from durationcanvas_ref 128684
to durationcanvas_ref 130348
yz 86 2020 explicitmsg "1.1. rozpocznijDiagnoze()"
show_full_operations_definition default show_class_of_operation default drawing_language default show_context_mode default
label_xy 322 69
msg 130732 synchronous
from durationcanvas_ref 130348
to durationcanvas_ref 130604
yz 101 2025 explicitmsg "1.1.1 rozpocznijDiagnoze()"
show_full_operations_definition default show_class_of_operation default drawing_language default show_context_mode default
label_xy 515 110
reflexivemsg 131244 synchronous
to durationcanvas_ref 131116
yz 152 2025 explicitmsg "1.2. Diagnozuj()"
show_full_operations_definition default show_class_of_operation default drawing_language default show_context_mode default
label_xy 711 131
2021-01-31 01:11:58 +01:00
end